QMA-Q1000



QMA-Q1000

QMA-Q1000

Elevator AC Drive Open Loop

General Specifications
Voltage Class 220 VAC 380 / 400/415VAC
Drive Input Drive Model Q1000-2R2-23A Q1000-3R7- 23A Q1000-5R5- 43A Q1000-7R5- 23A Q1000-3R7- 43A Q1000-5R5- 43A Q1000-7R5- 43A Q1000-011- 43A Q1000-015-43A
Rated Input Voltage Three-phase 200Vac to 240Vac, -15% to +10%
(170 Vac to 264 Vac)
Three-phase 380V to 480V, -15% to +10%
(323 Vac to 528 Vac)
Rated Input Current (A) 10.5 14.6 26 35 10.5 14.6 20.5 26 35
Rated Input Frequency 50/60 Hz, ±5% (47.5 to 63 Hz)
Drive Output Applicable Motor [kW] 2.2 3.7 5.5 7.5 3.7 5.5 7.5 11 15
[HP] 3 5 7.5 10 5 7.5 10.0 15 20
Output Current [A]*1 9 13 25 32 9 13 17.0 25 32
Power Capacity [kVA] 5.9 8.9 17 21 5.9 8.9 11 17 21
Overload Capacity 150% for 60 Sec & 180% for 3 Sec
Max. Output Voltage Three-phase 200 Vac to 240 Vac
(Proportional to Input voltage)
Three-phase 380 Vac to 480 Vac
(Proportional to Input voltage)
Max. Output frequency 100 Hz
Braking Recommended \ Power [W] 500 750 1200 1500 750 1200 1500 2500 3000
Recommended Resistance ≥65 ≥45 ≥22 ≥16 ≥130 ≥90 ≥65 ≥43 ≥32
Enclosure IP 21

*

: At 4 kHz carrier frequency without derating.
: The mounting dimensions are shown below.